Qhia cov deshengxin sab hauv tsev FFU daws teeb meem, koj ib qho kev daws teeb meem rau kev txhim kho thiab cov huab cua zoo nyob hauv koj lub chaw sab hauv. Peb cov ntau ntawm FFU (kiv cua lim lim) yog tsim los ntawm kev sib txuas ua pa tawm, xa cov kev ua tau zoo thiab lub zog txuag. Cov Nta Tseem Ceeb: Kev sib koom ua ke ntawm FFU tau tsim los kom haum ntau yam txheej txheem kev teeb tsa, kom muaj kev sib xyaw ua ke cov txheej txheem tsis muaj ntau yam uas txo qis downtime. Kev siv lim dej siab ua haujlwm: nruab nrog cov lim dej siab, peb cov kab mob uas muaj cov av muaj plua plav cua, thiab cov kab mob, thiab ib puag ncig huv si. Yuav tsum muaj lub zog thev naus laus zis: tau txais kev siv tshuab hluav taws xob siab dua, peb lub zog kom haum rau cov khoom siv hluav taws xob piv rau cov khoom siv. Kev ua haujlwm uas muaj peev xwm: Nrog rau kev tsom xam cov qauv acoustic, peb FFUs ua rau cov suab nrov tsawg, ua cov chaw ua haujlwm zoo li chaw haujlwm, thiab cov chaw kho mob. Ntse tswj kev sib raug zoo: peb cov kev hloov pauv ffu tau sib xyaw nrog ntau txoj kev sib koom ua ke hauv kev tswj hwm hauv tsev rau kev saib xyuas hauv tsev thiab tswj tau. Lub sijhawm ua kom ruaj khov thiab kev ntseeg tau: txua tsim los ntawm cov ntaub ntawv zoo thiab cov khoom siv hauv FFUs Vim li cas thiaj xaiv Deshengxin Sab Hauv Tsev FFU kev hloov kho tau? Cov kev tshaj lij thiab kev paub: Ua ib tus neeg muab kev ntseeg siab ntawm cov kev daws teeb meem hauv sab hauv tsev, deshengxin nqa tau xyoo kev txawj ntse thiab kev paub rau txhua qhov kev hloov pauv FFU hloov. Cov kev daws teeb meem: Peb nkag siab tias txhua qhov chaw sab hauv yog qhov tshwj xeeb. Yog vim li cas peb muab cov kev hloov kho ffu hloov kho kom haum rau koj cov kev xav tau tshwj xeeb thiab cov kev xav tau. Cov neeg siv khoom txhawb nqa zoo: Peb cov neeg siv khoom txhawb nqa zoo ib txwm muaj los muab kev pab, teb cov lus nug, thiab ua kom muaj kev hloov cov txheej txheem kev hloov pauv. Hloov kho koj cov huab cua sab hauv tsev zoo hnub no nrog Desehengxin sab hauv Tsev FFU kev hloov pauv. Ua cov txiaj ntsig ntawm cov txiaj ntsig ntawm cov cua tshuab nqus, txuag hluav taws xob, thiab ib puag ncig sab hauv tsev zoo dua.
Deshengxin, renowned for its comprehensive indoor air quality solutions, proudly presents our Indoor Replaceable FFU (Fan Filter Unit) specifically designed for seamless integration and ease of maintenance in cleanroom environments. This innovative product addresses the challenges traditionally associated with FFU replacements in cleanrooms, particularly the need to access ceiling-mounted units, making it an ideal choice for facilities seeking to minimize downtime and maintain pristine conditions.
Key Advantages for Cleanroom Replacements:
1. No-Ceiling-Access Design: The hallmark feature of our Indoor Replaceable FFU is its innovative design that eliminates the need for technicians to climb onto ceilings or scaffolding for replacements. With our user-friendly design, maintenance can be safely and efficiently carried out from ground level, significantly reducing the risk of contamination and streamlining the replacement process.
2. Preserving Cleanroom Integrity: By eliminating the need for ceiling access, our FFU replacements minimize the disruption of cleanroom conditions. There's no need to move furniture, disassemble equipment, or close down entire areas, ensuring that cleanliness and operational continuity are maintained throughout the process.
3. Quick and Easy Installation/Replacement: Our replaceable FFUs feature intuitive design elements such as quick-release mechanisms and clear installation instructions, enabling even inexperienced personnel to perform replacements with minimal training. This leads to reduced labor costs and faster return to operational status.
4. Full-Chain Production Expertise: Deshengxin's strength lies in our ability to offer a comprehensive range of indoor air quality products, backed by a fully integrated production chain. From motor technology to filtration media, every component of our FFUs is carefully crafted and rigorously tested to ensure the highest standards of quality and performance. This vertical integration allows us to maintain strict control over product quality and offer customized solutions tailored to our clients' unique needs.
5. Ongoing Support and Service: Recognizing the importance of ongoing support for cleanroom facilities, Deshengxin provides comprehensive service packages that include regular maintenance checks, preventive maintenance programs, and rapid response times for any unexpected issues. Our dedicated customer service team stands ready to assist you every step of the way.
In conclusion, the Deshengxin Indoor Replaceable FFU is a game-changing solution for cleanroom facilities seeking to optimize air quality, minimize downtime, and maintain the highest levels of cleanliness and operational efficiency. With our full-chain production expertise and commitment to innovation, we are dedicated to delivering exceptional value and performance to our customers.
1 |
|
5 |
Motor |
2 |
|
6 |
HEPA filter |
3 |
|
|
|
4 |
|
|
|
It is powered by a high-efficiency motor that can be adjusted to three speeds and low power consumption and low operating expenses (DC motors are also chosen to save energy). The motor was developed and manufactured by DSX and is able to be adjusted in accordance with the needs of the customer.
Filter materials could be fiberglass, PTFE or optional HEPA and ULPA filtering systems with various filtering levels. Filter grade options include H13, U14 U15 and U16.
In addition to FFUs that are used in normal situations, we also offer FFUs that are specifically designed for industries that use lithium batteries, extremely thin FFUs for spaces with limited space, and explosion-proof FFUs. As a leading FFU producer, we are able to customize FFUs to suit various situations for our customers.
Each of DSX FFUs is assembled in cleanrooms to guarantee an extremely clean environment. Our FFUs strictly follow the strictest guidelines and adhere to cleanroom procedures throughout the production process. This strict approach ensures we can guarantee that the FFUs are clean of any contamination, which is essential to ensure optimal performance while maintaining clean working environments across a variety of applications.
Customizable FFU Control System: Enhancing Efficiency and Performance
We have developed our FFU control system was developed and created by our own engineers, offering unparalleled flexibility and customization. With attention to particulars the control system we use offers an array of customizable options to satisfy specific customer needs. If it's creating the interface for control, altering rates of baud, or choosing the preferred option for display language Our control system is able to be customized to meet different communication styles and requirements of the customer. This flexibility allows for an easy integration into existing systems, and increases the overall effectiveness and efficiency for our FFUs.
DESCRIPTION | Size(L*W*HMM) (Including HEPA) |
Air velocity (m3/h) |
Air flow (m/s) | Noise | Position of testing noise | Shell material | Power Supply | Rated power |
Ultra thin FFU | 1175*575*180 | 1000 | 0.45m/s (±20%) | ≤59Db | 1.2m far below the filter | Zn-Al coated plate/ stainless steel |
220v/110V | 0.17kw |
FFU575575 | 575*575*320 | 500 | 0.45m/s (±20%) | ≤59Db | 1.2m far below the filter | Zn-Al coated plate/ stainless steel |
220v/110V | 0.12kw |
FFU615615 | 615*615*320 | 700 | 0.45m/s (±20%) | ≤59Db | 1.2m far below the filter | Zn-Al coated plate/ stainless steel |
220v/110V | 0.12kw |
FFU915615 | 915*615*320 | 900 | 0.45m/s (±20%) | ≤59Db | 1.2m far below the filter | Zn-Al coated plate/ stainless steel |
220v/110V | 0.12kw |
FFU1175575 | 1175*575*320 | 1000 | 0.45m/s (±20%) | ≤59Db | 1.2m far below the filter | Zn-Al coated plate/ stainless steel |
220v/110V | 0.12kw |
FFU1175*1175 | 1175*1175*350 | 2000 | 0.45m/s (±20%) | ≤59Db | 1.2m far below the filter | Zn-Al coated plate/ stainless steel |
220v/110V | 0.18kw |
The size and other parameters can be customized according to the clients' demands.
Partial custom parameters are as follows.
1.FFU parameters(CE):
Model |
DSX-FFU01-02 |
DSX-FFU01-02 |
DSX-FFU01-03 |
DSX-FFU02-02 |
DSX-FFU02-04 |
FFU dimension (mm) |
575 x 575 x 210 |
1175 x 575 x 210 |
1175 x 575 x 270 |
1175 x 1175 x 270 |
1175x1175x210 |
FFU material |
SUS304 / SUS201 / SUS 316 / SUS430 / SGLC / Powder coated |
||||
Fan |
AC |
||||
Input |
230ACV/60HZ/1P |
||||
Speed (m/s) |
0.45~1 m/s±20% at high speed |
||||
Control type |
Manual |
||||
HEPA Height (mm) |
50 / 70 Optional |
||||
HEPA filter material |
Glass fibre |
||||
HEPA efficiency |
H13 / H14 /U15 |
||||
Operating temperature |
10~40℃ |
||||
Structure type |
Split type |
||||
Installation mode |
Horizontal / Vertical |
Model |
Ultrathin type |
|||
FFU dimension (mm) |
875X575X160 |
1350X460X160 |
1600X460X160 |
Other dimension |
FFU material |
SUS304 / SUS201 / SUS 316 / SUS430 / SGLC / Powder coated |
|||
Fan |
AC / EC |
|||
Input |
220ACV/50HZ/1P |
|||
Speed (m/s) |
0.45~0.7 m/s±20% at high speed |
|||
Control type |
Manual / RS485 |
|||
HEPA Height (mm) |
50 / 70 Optional |
|||
HEPA filter material |
Glass fibre |
|||
HEPA efficiency |
H13 / H14 /U15 |
|||
Operating temperature |
10~40℃ |
|||
Structure type |
Split type |
|||
Installation mode |
Horizontal / Vertical |
Model |
Conventional type |
||||
FFU dimension (mm) |
575x575x230 |
765X510X230 |
1000X520X230 |
1175X575X230 |
Other |
FFU material |
SUS304 / SUS201 / SUS 316 / SUS430 / SGLC / Powder coated |
||||
Fan |
AC / EC |
||||
Input |
220ACV/50HZ/1P |
||||
Speed (m/s) |
0.45m/s±20% at high speed |
||||
Control type |
Manual / RS485 |
||||
HEPA Height (mm) |
50 / 70 Optional |
||||
HEPA filter material |
Glass fibre |
||||
HEPA efficiency |
H13 / H14 /U15 |
||||
Operating temperature |
10~40℃ |
||||
Structure type |
Split type |
||||
Installation mode |
Horizontal / Vertical |
Model |
High speed type |
|||
FFU dimension (mm) |
430X430X270 |
1175X575X270 |
1175X175X270 |
Other |
FFU material |
SUS304 / SUS201 / SUS 316 / SUS430 / SGLC / Powder coated |
|||
Fan |
AC / EC |
|||
Input |
220ACV/50HZ/1P |
|||
Speed (m/s) |
1m/s±20% at high speed |
|||
Control type |
Manual / RS485 |
|||
HEPA Height (mm) |
50 / 70 Optional |
|||
HEPA filter material |
Glass fibre |
|||
HEPA efficiency |
H13 / H14 /U15 |
|||
Operating temperature |
10~40℃ |
|||
Structure type |
Split type |
|||
Installation mode |
Horizontal / Vertical |
Model |
F-DA190X1-SUS304-400X400X100-F50H13 |
F-DA190X1-SUS304-430X430X120-F70H13 |
FFU dimension (mm) |
400 X 400 X 100 |
400 X 400 X 120 |
FFU material |
SUS304 / SUS201 / SUS 316 / SUS430 / SGLC / Powder coated |
|
Fan |
AC |
|
Input |
220ACV/50HZ/1P |
|
Speed (m/s) |
0.25m/s±20% at high speed |
|
Control type |
Manual |
|
HEPA Height (mm) |
50 / 70 Optional |
|
HEPA filter material |
Glass fibre |
|
HEPA efficiency |
H13 / H14 /U15 |
|
Operating temperature |
10~40℃ |
|
Structure type |
Split type |
|
Installation mode |
Horizontal / Vertical |
HEPA grade |
H13 |
H14 |
U15 |
HEPA eff. |
99.99%@0.3um |
99.995%@0.3um |
99.9995%@0.3um |
Material |
Glass fibre |
||
Frame material |
Aluminium alloy |
||
Net cover |
High quality steel baking paint (double-sided) |
||
Gasket |
High density synthetic rubber |
Model |
3 speed type FFU |
||||||
FFU dimension (mm) |
600X400 |
700X400 |
575X575 |
1175X575 |
1350X400 |
1470X400 |
Other |
FFU material |
Powder coated |
||||||
Fan |
AC |
||||||
Input |
220-230ACV/50HZ/1P |
||||||
Speed (m/s) |
0.45-1.0m/s Adjustable |
||||||
Control type |
Manual / RS485 |
||||||
HEPA Height (mm) |
50 / 70 / 90 Optional |
||||||
HEPA filter material |
Glass fibre |
||||||
HEPA efficiency |
H13 / H14 /U15 |
||||||
Operating temperature |
10~40℃ |
||||||
Structure type |
Split type / Integrated |
||||||
Installation mode |
Horizontal / Vertical |
7.FFU parameters(3 speed room side replacement type ):
Model |
3 speed room side replacement typeFFU |
||||||
FFU dimension (mm) |
600X400 |
700X400 |
575X575 |
1175X575 |
1350X400 |
1470X400 |
Other(其他) |
FFU material |
Powder coated |
||||||
Fan |
AC |
||||||
Input |
220-230ACV/50HZ/1P |
||||||
Speed (m/s) |
0.45-1.0m/s Adjustable |
||||||
Control type |
Manual / RS485 |
||||||
HEPA Height (mm) |
50 / 70 / 90 Optional |
||||||
HEPA filter material |
Glass fibre |
||||||
HEPA efficiency |
H13 / H14 /U15 |
||||||
Operating temperature |
10~40℃ |
||||||
Structure type |
Integrated |
||||||
Installation mode |
Horizontal / Vertical |
8.FFU parameters(EC energy saving type EC节能型):
Model |
EC energy saving type FFU |
||||||
FFU dimension (mm) |
600X400 |
700X400 |
575X575 |
1175X575 |
875X575 |
1010X610 |
Other(其他) |
FFU material |
Powder coated |
||||||
Fan |
EC |
||||||
Input |
220-230ACV/50HZ/1P |
||||||
Speed (m/s) |
0.45-1.0m/s Adjustable |
||||||
Control type |
RS485 |
||||||
HEPA Height (mm) |
50 / 70 / 90 Optional |
||||||
HEPA filter material |
Glass fibre |
||||||
HEPA efficiency |
H13 / H14 /U15 |
||||||
Operating temperature |
10~40℃ |
||||||
Structure type |
Integrated |
||||||
Installation mode |
Horizontal / Vertical |